CN
+86 13506548868
Service
Service
Concept
  • Project manager responsibility system
    01
    Project manager responsibility system
    With the four principles of "smooth landing, smooth production, training in place, and timely after-sales", we ensure that customers achieve project design expectations and effectively protect customers' rights and interests;
  • Round-the-clock service
    02
    Round-the-clock service
    7*24 hours professional service desk, record all customer information, access support at any time;
  • Return visit plan
    03
    Return visit plan
    Regular telephone return visits, maintenance of some areas, so as to prevent failure losses and save costs;
  • Technical training
    04
    Technical training
    Provide training services and develop effective solutions;
  • Service network
    05
    Service network
    Relying on the advantages of the group, the establishment of a perfect service office, quick response to solve problems.
Project manager responsibility system
01
Project manager responsibility system
With the four principles of "smooth landing, smooth production, training in place, and timely after-sales", we ensure that customers achieve project design expectations and effectively protect customers' rights and interests;
Round-the-clock service
02
Round-the-clock service
7*24 hours professional service desk, record all customer information, access support at any time;
Return visit plan
03
Return visit plan
Regular telephone return visits, maintenance of some areas, so as to prevent failure losses and save costs;
Technical training
04
Technical training
Provide training services and develop effective solutions;
Service network
05
Service network
Relying on the advantages of the group, the establishment of a perfect service office, quick response to solve problems.
FAQ
Q:What role does the electric operating mechanism play on the circuit breaker?
A:

The circuit breaker has a high mechanical life, and the operation is convenient and reliable: all the indicating functions and information of the circuit breaker are still clearly displayed, including the setting and indication of the trip unit; Barrier function, and a padlock function. If you need to operate with the communication function, you need to use a special electric operation organization, the communication electric operation organization must be connected to the BSCM module in order to accept the split and close instructions, its operation is the same as the standard electric operation organization.

Device and connection: all device methods (fixed, piercing, extraction) and connection methods can be completed; The terminal behind the front cover of the tissue module can only be connected to 2.5mm2.

Electric operation organization operation: The type of operation is selected by manual/active selection of a switch that can be closed with a clear lead seal cover. Active operation When the switch is in the "active" position, the ON/OFF(I/O) button and the manual energy storage organization are determined. Switching can be controlled by two pulse or self-persisting signals. MN or MX coil tripping spring active energy storage. Manual reset is required after the electrical fault trip. Manual operation When the switch is in the "manual" position, the ON/OFF(I/O) button can be used. A microswitch connected to a manual position in the electrically operated organization can indicate this information over long distances. Through the "ON,OFF" two buttons control. Press the energy storage handle nine times to store energy in the tissue. Padlock can be determined when OFF orientation.